tianzheng-batch-polyline-dimension
Automate native Tianzheng/AutoCAD dimensions for selected or runtime-discovered polylines, including ARC included-angle and LINE dimensions, ordinary exterior-band layout, exceptional collapsed-angle
Files343
View on GitHubSKILL.mdskills/tianzheng-batch-polyline-dimension/SKILL.md
GitHubTianzheng Batch Polyline Dimension
Use this Skill as the entry for 自动批量多段线尺寸. Its runtime/ directory contains the existing business implementation and native-control source. Reuse that code instead of recreating the geometry algorithm from prose. Package version: 1.1.1; publication does not promote the complete command's validation maturity.
Start from authority
- Read migration.md. Use bundled
runtime/as the source root unless the receiver explicitly selects an equivalent local checkout; do not look for the author's private computer or task IDs. - Read the receiver's current instructions and the runtime's source/build/input documentation. Local software, owner, document, scope and permission must be bound to the receiver's real environment.
- Run
scripts/inspect_capability.ps1to verify the packaged source manifest. This read-only check never starts CAD and does not authorize execution. - Runtime owner, selection ledger, scope, task handoff and return records are new local inputs, not author data to copy. If using the original governed controller, provide its same-schema inputs or equivalent host adapters while preserving scope/hash/owner checks.
- Read
references/project-contract.mdbefore changing formulas or claiming acceptance. Default to offline preparation; native mutations require an authorized isolated drawing and a fresh exact session binding.
Reuse the two-layer implementation
- Business layer: runtime geometry discovery, native ARC/LINE dimension generation, source mapping, first-pass exterior layout, and the narrow exceptional rescue pass.
- Observer layer: identity, ACK/COMPLETE, timings, semantic and endpoint audits, native-grip inventory, readable screenshot, and return delivery.
Keep the business path short. Do not insert heavyweight probes into already-fast stages. Enable targeted diagnostics only at a failed boundary or for a known difficult candidate.
Preserve dimension semantics
- ARC objects must remain native included-angle dimensions expressed in degrees. Arc length is a semantic failure even if the picture looks plausible.
- LINE objects must remain native linear dimensions and must not receive a degree marker.
- Require runtime source mapping and endpoint association. A visible object without a valid mapping is not a successful dimension.
- Ordinary objects use the shared exterior-band formula first. Do not move every object merely because one exceptional corner needs rescue.
Handle the exceptional collapsed-angle case
Apply the rescue chain only when runtime measurements identify the anomaly. Never match a fixed handle, coordinate, segment number, bounding box, or object count.
- Establish or replace an endpoint-valid native angle candidate.
- Accept the curve side and posture before moving text.
- Apply the runtime outer-band formula.
- If the text anchor still lies on or crowds the dimension curve, move grip 4 only.
- Derive the grip-4 WCS delta from a same-source, shared-endpoint, rank-2 degree peer normalized by measured text height
H. - Pass planner
DX/DYthrough unchanged. The controller must not recalculate the vector. - Re-inventory the complete native set and produce a readable screenshot.
Execute through the governed lane
Separate planning/inspection from the one owner that actually drives Tianzheng; task titles do not confer permission. The receiver may use its own equivalent coordination rather than copying the author's project task system.
For a real CAD mutation:
- Verify no active CAD lease conflict.
- Bind a fresh immutable handoff to the actual target, permitted actions, file hashes and save policy. When using the original controller schema, satisfy its real input contract; do not delete assertions or fabricate READY/PASS.
- Dispatch only to the receiver's exact execution owner, never an author task ID.
- Permit only the actions named by the handoff. Default test policy is
save=falseandretry=0. - The bounded executor stops at its contract boundary. The source task retains its active outcome and uses the host's existing wait/return mechanism to review the immutable result; do not replay the run or imply automatic continuation without an actual wake-up path.
An explicit current contract may allow saving a unique checkpoint through its accepted save-copy chain. This never authorizes overwriting the source, reusing a closed historical owner or silently retrying a terminal run. Without that authority keep save=false; a saved checkpoint is not formal delivery acceptance.
Judge completion precisely
- A static test, DLL load, ACK, screenshot, or partial survivor set alone is not full success.
- Report generation coverage, semantic correctness, endpoint association, layout targets, protected-grip drift, source drift, screenshot result, business time, observer time, failures, and next legal gate.
- The special text peer-normal component has a current-board 3-of-3 stability record. This does not establish three complete blank-to-final runs and does not establish cross-structure DWG generality.
- Keep the whole command package at its registry maturity until its own promotion gates pass.
Read current-scope reuse and acceptance when reusing the common-band chain, diagnosing coarse collision flags, or interpreting sample acceptance and saved/reopened evidence. The historical special-text result above is not a complete current-state report.
Keep the package clean
- Keep current run directories, drawings, screenshots, identities and credentials outside the distributed source. Bundled source dependencies may include a versioned helper required by the selected call chain; that does not make every optional action a default route.
- Do not revive routes listed as forbidden or rejected by the project.
- Fix repeatable workflow faults in the shared layer and add a regression; do not accumulate one-run workarounds.
- Follow the current handoff's explicit save/checkpoint authority; otherwise preserve test drafts unsaved. A checkpoint is not a formal accepted deliverable.