Get S32FlashTool Version

Safe, read-only probe for the installed S32FlashTool CLI and/or the MCP server identity. No target access, no board required, no side effects.

When to use

  • Verify S32FlashTool is installed and identify its version/build.
  • Verify the MCP server is reachable and check installed-vs-validated version.
  • First cheap check before any hardware workflow (port discovery, flash ops, GUI/RPC automation).

Not for target connectivity, serial-boot state, MCU identity, or target/algorithm compatibility. Use s32flashtool-read-mcuid, s32flashtool-list-available-serial-communication-interfaces, or s32flashtool-supported-devices-per-platform for those.

Do not use this skill for

Do not use this skill to:

  • verify target connectivity
  • verify serial boot mode
  • identify the MCU on the board
  • prove that a target/algorithm combination is supported
  • replace a communication test such as ping, hello, or mcuid

If the user wants hardware communication validation, use the appropriate connectivity or operation skill after this one.

Shared references

  • Apply shared rules from s32flashtool-agent-rules-minimal/SKILL.md.
  • Use s32flashtool-workflow-index/SKILL.md to select the correct operation skill when version lookup is only one step in a larger workflow.

Which action to call

get_runtime_info is the default. cli_get_version is a fallback when only the raw CLI banner is wanted or when isolating the CLI layer for debugging.

Cost note: both actions spawn the CLI once when sft_folder is supplied. get_runtime_info is a strict superset at the same cost — it returns MCP identity, target_tool_version, and a tool_status: matches | mismatch verdict in addition to the CLI banner.

Question Call
Any version info; workflow starting soon get_runtime_info with sft_folder if known, else without
MCP identity only, no install known get_runtime_info (no sft_folder) — cheap, no CLI spawn
Raw CLI banner only (debug / narrow consumer) cli_get_version with sft_folder

Parameters

  • sft_folder: absolute path to the S32FlashTool installation root (e.g. C:\NXP\S32FlashTool_2.4.3).
    • get_runtime_info: optional. If not specified, only the MCP manifest is returned.
    • cli_get_version: optional. If not specified, falls back to the value configured in the MCP settings.

Example responses

get_runtime_info with sft_folder:

{
  "mcp_server_name": "s32flashtool",
  "mcp_server_version": "1.0.0",
  "target_tool_version": "2.4.3",
  "installed_tool": {
    "detected": true,
    "version": "2.4.3",
    "installation_path": "C:\\NXP\\S32FlashTool_2.4.3",
    "docs_path": "C:\\NXP\\S32FlashTool_2.4.3\\doc",
    "tool_status": "matches",
    "banner": "S32 Flash Tool 2.4.3. Build 260812. Copyright 2019 - 2026 NXP"
  }
}

cli_get_version:

{
  "sft_folder": "C:\\NXP\\S32FlashTool_2.4.3",
  "version": "S32 Flash Tool 2.4.3. Build 260812. Copyright 2019 - 2026 NXP"
}

Report the version verbatim and label its source, e.g. Installed CLI: S32 Flash Tool 2.4.3, build 260812 or MCP s32flashtool 1.0.0, validated against tool 2.4.3 (installed tool matches).

Validation loop

A successful execution normally returns:

  • a version string, build string, or identification string
  • without requiring any target communication

Agents should treat this as evidence of tool availability only.

It does not validate:

  • serial boot mode
  • board power or wiring
  • COM port correctness
  • target reachability
  • flash algorithm compatibility

Error handling

  • Report status, status_text, and any message verbatim; do not guess a version.
  • If cli_get_version fails, confirm sft_folder is correct and points at the installation root.
  • If get_runtime_info returns tool_status: mismatch, warn the user that the installed tool differs from the MCP-validated version; behavior may deviate from documented defaults.
  • A version-query failure says nothing about target reachability or wiring.

Guardrails

  • Read-only, diagnostic. Never invokes a writing tool.
  • Success proves tool availability only — not board power, port correctness, serial-boot state, or target reachability. Follow up with a communication or operation skill for hardware validation.