async-runtime-safety

Use when Rust code adds or changes an `async fn`, an `.await`, a spawned task, a `tokio::select!`, a timeout, a lock shared between tasks, an `#[async_trait]` impl, or reads time or generates identifi

SKILL.md

GitHub

Async Runtime Safety

Profile keys consumed

  • make.static_analysis — the strict static analysis that reports a lock guard held across .await, a banned blocking or wall-clock API and an implicit pointer clone; null degrades to a manual review of the diff
  • make.unit_tests — the unit suite, where paused-clock tests prove timeouts and cancellation without real time; null is recorded as a capability gap
  • make.integration_tests — the database-backed suite, where timeouts and cancellation are proven against the real dependencies; null is recorded as a capability gap

Context

The service runs on the multi-threaded tokio runtime: axum handlers, the command and query buses, #[async_trait] ports and the database driver all share a small pool of worker threads. Four failure classes are invisible to the compiler and expensive in production:

  • Blocking in async code. A synchronous file read, a thread sleep or a synchronous DNS lookup parks a worker thread; every task on that thread stalls, request budgets expire and health probes time out.
  • A lock guard across .await. A std::sync guard held across a suspension point makes the future non-Send or deadlocks the runtime; even an async mutex guard held across slow I/O serializes every caller.
  • Cancellation. Any future can be dropped at any .await: by a timeout, by tokio::select!, or by the server when the client disconnects or the request budget expires. Code that is not cancellation-safe leaves half-applied state.
  • Hidden time and randomness. Reading the wall clock or generating identifiers inline makes behaviour untestable; the template bans those APIs and routes them through the Clock and UuidGenerator ports.

The rules apply to code reachable from an async fn or a future. Synchronous start-up code that runs before the runtime starts is outside them. The repository's own rules in AGENTS.md and its architecture document win where they are stricter.

Task

Make every async path of the change non-blocking, guard-free across .await, cancellation-safe and time-bounded, with time and identifiers read only through ports, and prove it with the targets mapped by make.static_analysis, make.unit_tests and make.integration_tests.

Success criteria

  • No blocking call is reachable from async code: file, sleep and DNS calls use their tokio equivalents, and CPU-heavy or blocking-library work runs in tokio::task::spawn_blocking.
  • No lock guard (std::sync, tokio::sync, RefCell) is alive across an .await.
  • Every await on an external dependency is bounded by a timeout whose duration comes from configuration, and every tokio::select! branch is cancellation-safe.
  • Every method of an #[async_trait] impl is a single delegation to an inherent async fn of the same type.
  • Time is read only through Clock (elapsed time through tokio::time::Instant), identifiers come only from UuidGenerator, and every shared pointer copy is written Arc::clone(&x).
  • The mapped targets pass; each null target is recorded not run (capability absent) and the result is SUCCESS-WITH-REPORT, never a claimed pass.

Steps

1. Resolve the profile and the async surface

Read make.static_analysis, make.unit_tests and make.integration_tests from the profile. List the async surface of the diff: every added or changed async fn, .await, tokio::spawn, tokio::select!, #[async_trait] impl, Mutex, RwLock and RefCell field, and every call that reads time or creates an identifier. When the list is empty, record NOT APPLICABLE: no async code, shared state, time or identifier source in the diff and stop.

2. Replace blocking calls

Blocking call in async code Non-blocking replacement
std::fs (read, write, File::open, metadata, create_dir_all) tokio::fs with the same names
std::thread::sleep tokio::time::sleep
synchronous DNS (std::net::ToSocketAddrs, to_socket_addrs) tokio::net::lookup_host
std::sync::mpsc receive, blocking std::io reads tokio::sync::mpsc, tokio::io
CPU-heavy work (hashing, compression, large serialization) or a library that only offers a blocking API tokio::task::spawn_blocking
block_on (futures or Handle::block_on) inside a task an .await; never nest a runtime

spawn_blocking returns a JoinHandle: await it and convert the JoinError into the layer's error as #[source], never unwrap it. In the sketch below, hash is the blocking work and <Entity>Error::worker is a constructor of the context's error enum that boxes the JoinError as its source:

let digest = tokio::task::spawn_blocking(move || hash(&payload))
    .await
    .map_err(<Entity>Error::worker)?;

Before an infrastructure or application crate calls tokio::fs or spawn_blocking, confirm that tokio is on that layer's allow-list in architecture.toml. Domain crates stay synchronous apart from #[async_trait] port signatures. A missing allow-list entry is a dependency-policy decision (escalated, never edited here): see dependency-policy.

3. Release every lock before .await

Static analysis reports a std::sync guard (clippy::await_holding_lock) or a RefCell borrow (clippy::await_holding_refcell_ref) across .await. Apply the same rule to tokio::sync::Mutex and RwLock guards, which the lint does not see: copy or take what you need inside a block, let the guard drop at the end of the block, then await.

let pending = {
    let mut queue = self.queue.lock().await;
    std::mem::take(&mut *queue)
}; // the guard is dropped here, before the next `.await`
self.publisher.publish(pending).await?;

Prefer state that needs no lock across tasks: an atomic for a counter or a flag (clippy::mutex_atomic), a tokio::sync::watch or mpsc channel for hand-over, or an owned value moved into the task. A std::sync::Mutex is allowed only when every guard is dropped before the next .await, and its poison error is converted, never unwrapped.

4. Cancellation safety and timeouts

  • Bound every external await. Wrap each call to a database, broker, outbound HTTP client or probe in tokio::time::timeout(budget, call).await, with budget read from configuration in the composition root (see configuration-management), never a literal duration in a handler. Convert the Elapsed error into a typed variant of the layer's error (for example Unavailable), so it reaches the client through rust-error-handling.
  • Make each await a safe drop point. A logical write becomes visible in one awaited step (one repository call, one transaction); never split it across two awaits without a way to recover. Side effects that must follow a write (event publication, cache invalidation) run after the write has succeeded, and their failure is handled, not left half-done.
  • Select only cancellation-safe branches. In tokio::select!, use futures that lose nothing when dropped (mpsc::Receiver::recv, watch::Receiver::changed, tokio::time::sleep). A future that buffers partial progress (read_exact, read_to_end, a multi-step operation) is pinned outside the loop and polled by &mut reference, so a lost race does not restart it.
  • Own every spawned task. Keep the JoinHandle of a tokio::spawn and await or abort it on shutdown; never detach a task that writes state, and never discard the handle with let _ = (clippy::let_underscore_future).
  • Test without real time. Unit tests of timeouts and retries use #[tokio::test(start_paused = true)] and tokio::time::advance; elapsed time is measured with tokio::time::Instant, which follows the paused clock.

5. Delegate #[async_trait] methods to an inherent async fn

The body of every method in an #[async_trait] impl is one delegation to an inherent async fn of the same type. The macro rewrites the body into a boxed future, so coverage records no line counts there and the complexity check does not see it; logic placed there would pass both gates unexamined.

#[async_trait::async_trait]
impl CommandHandler<Create<Entity>> for Create<Entity>Handler {
    async fn handle(&self, command: Create<Entity>) -> Result<(), <Entity>Error> {
        self.create(command).await
    }
}

Synchronous trait methods (for example Clock::now) are not affected.

6. Read time and identifiers through ports

  • Time comes from the Clock port (fn now(&self) -> SystemTime) and identifiers from the UuidGenerator port (fn generate(&self) -> Uuid), both injected as Arc<dyn Clock> and Arc<dyn UuidGenerator> through the handler's constructor.
  • The wall-clock and identifier constructors (SystemTime::now, Instant::now, Uuid::new_v4, Uuid::now_v7) are on the disallowed-methods list of clippy.toml; read that list at runtime for the full set. Only the adapters that own a banned API call it, each with one item-level #[expect(clippy::disallowed_methods, reason = "…")].
  • Tests use the clock and generator doubles of the shared test-support crate, or the paused tokio clock, never real time.

7. Copy shared pointers explicitly

Write Arc::clone(&x), never x.clone(), for an Arc or Rc (clippy::clone_on_ref_ptr), so the cheap pointer copy is visible and cannot be confused with a deep clone. Ports are shared as Arc<dyn Port> and carry Send + Sync + std::fmt::Debug as supertraits, so the futures that capture them stay Send.

8. Verify with the mapped targets

Run, in this order, each mapped target as verification-workflow prescribes (in the background, logged and polled to the end):

  1. make.static_analysis — the lock, banned-API and pointer-clone lints;
  2. make.unit_tests — the paused-clock tests of timeouts, cancellation and delegation;
  3. make.integration_tests — the database-backed tests; run it alone, never in parallel with another database-backed target, because it resets the shared test database.

For each null key, record not run (capability absent) (degrade D1). When make.static_analysis is null, review the added lines of the diff for std::fs::, std::thread::sleep, to_socket_addrs, block_on, .lock() or .borrow() followed by an .await in the same scope, SystemTime::now, Instant::now, Uuid::new_v4, Uuid::now_v7 and .clone() on an Arc, and fix every hit. A target that cannot start (no toolchain, no reachable container engine) is recorded not run (no toolchain) or not run (no Docker) and handed back to the calling stage, which escalates; it never counts as a pass.

Constraints

  • Never call a blocking API from async code, never nest a runtime with block_on, and never unwrap a JoinError, a poisoned lock or an Elapsed.
  • Never hold a lock guard across .await, whichever mutex type it comes from.
  • Never await an external dependency without a timeout, and never hard-code the timeout duration outside the configuration.
  • Never put logic in an #[async_trait] method body; it delegates to an inherent async fn.
  • Never read the wall clock or create an identifier outside the Clock and UuidGenerator adapters, and never weaken the disallowed-methods list or the lint levels: clippy.toml and [workspace.lints] are protected configuration. A finding that only such a change would clear is escalated with BLOCKED: protected configuration <path> — needs approved-config-change and a session restarted with ALLOW_PROTECTED_CONFIG_EDIT=1.
  • Never write .clone() on an Arc or Rc; write Arc::clone(&x).
  • Never run the integration target in parallel with another database-backed target.
  • The fix loop is bounded by the calling stage's iteration guard (5). The same finding after a fix, or the guard exhausted, ends the loop with the escalation block below; there is no further retry.

Verification

  • Targets-run rows, in the FR-1 vocabulary, one per key: <target>: passed | failed | not run (<reason>) for make.static_analysis, make.unit_tests and make.integration_tests.
  • The async surface listed in step 1, each item with the rule that covers it (steps 2 to 7) and the test that proves it, or NOT APPLICABLE with the reason.
  • Evidence for the EXECUTE verdict of this skill in the triage table: the targets-run rows plus the list of timeouts added (call, configuration source of the budget) and of spawn_blocking uses, or none.

Escalation

When the loop ends without a pass, or a fix needs protected configuration or a new allow-list entry, print the canonical block with the calling stage's id and exit string:

=== SDLC ESCALATION ===
stage: <stage-id>
iteration: <n>/5
exit_condition: <exit string of the calling stage, verbatim>
status: NOT MET
blocking_finding: <file:line> <lint, test name or rule>
iteration_log: <one line per iteration: "<n>: <what ran> -> <result>">
recommended_action: <the human decision, for example a protected change with ALLOW_PROTECTED_CONFIG_EDIT=1>
=== END ===